纯净水设备自动化程度非常高,设计精密,结构紧凑,适合大型工业企业使用。纯净水设备是采用反渗透技术研发而成,反渗透膜造价成本高,所以要正确的维护和保养纯净水设备,可以避免安全隐患的发生。下面来介绍一下纯净水设备正确的维护和保养方法。
The pure water equipment is highly automatic, precise in design, compact
in structure, and suitable for large industrial enterprises. The pure
water equipment is developed by reverse osmosis technology, and the cost
of RO membrane is high. Therefore, it is necessary to maintain and
maintain the purified water equipment correctly, so the occurrence of
safety hazards can be avoided. The following describes the correct
maintenance and maintenance methods of purified water equipment.
1、反渗透设备的总进水量由RO进水调节阀来控制,如果反渗透设备进水量没有变化,则不要乱动RO进水调节阀,严禁全开或全闭;RO浓排调节阀用来调整系统回收率,如回收率没有变化,则不要乱动浓排调节阀,绝对禁止全开或全闭。
1. The total water inflow of RO equipment is controlled by RO water
inlet regulating valve. If the inflow of RO equipment does not change,
do not move the RO inlet regulating valve, and it is strictly forbidden
to open or close completely; Ro concentrated discharge regulating valve
is used to adjust the recovery rate of the system. If the recovery rate
has not changed, do not move the concentrated discharge regulating
valve, and it is absolutely forbidden to open or close completely.
2、纯净水设备机械过滤器定期反洗。反洗时进行压缩空气气体摩擦,反洗合格后静置10min左右再正洗,正洗出水合格后方可投入使用,勿将空气带入反渗透膜。
2. Mechanical filter of purified water equipment is backwashed
regularly. During backwashing, the compressed air gas shall be rubbed.
After the backwashing is qualified, it shall be put into use after it is
still for about 10min, and then it can be put into use after the
positive washing water is qualified. Do not bring air into the reverse
osmosis membrane.
3、操作工应在每小时对运行参定网站建设 伺服液位仪 防撞墙模具 唐山护栏 钢纤维 天津除甲醛 保定铝型材数进行记录,主要内容应包括:
3. Operators shall record the operation parameters every hour, and the main contents shall include:
进水:PH值,电导率,压力,SDI,水温;
Water inflow: pH value, conductivity, pressure, SDI, water temperature;